Know your data center
conditions. Right now.
Wire-free sensors for temperature, humidity, power, fluid detection, air pressure, and more — placed exactly where you need them, with no cabling required.
Works in any existing data center.
Wire-free installation means no disruption to live operations. Add sensors to existing racks and cabinets without downtime. Retrofits to any cabling infrastructure — or none at all.
A sensor for every condition you need to monitor.
View all sensor specsRack-level temp and humidity. Surface-mount, battery-powered, excellent battery life.
Remote probe for shielded spaces — under raised floors, inside ductwork, freezers.
Film-based fluid sensor. Instant alert on contact. Fast, wire-free installation.
PinPoint — detects both presence AND exact location of fluid along a long cable run.
Monitors open/closed state on any door — cabinets, cages, IT closets, server rooms.
Integrates legacy or third-party equipment with dry contact terminals into real-time monitoring.
Differential pressure across raised floors — identifies airflow problems affecting cooling efficiency.
PinPoint — fluid detection
that tells you exactly where.
Not just "there is a leak somewhere." PinPoint identifies the precise location of fluid along a cable run — critical for liquid cooling environments where leaks cause catastrophic damage.
Three layers. One complete solution.
From physical tag to software intelligence — RF Code connects every layer of your infrastructure into a single real-time system of record.
Wire-free sensors
Battery-powered sensors are placed exactly where readings are needed — on racks, cabinet doors, under floors, inside ductwork. No cabling, no cable trays, no downtime to install.
Active RF network
Sensors transmit data wirelessly to the nearest RF Code reader — continuously, in real time. Readers support up to 1,400 sensors simultaneously with a 300ft read range.
CenterScape software
All sensor data streams into CenterScape for visualization, alerting, trending, and integration with DCIM, BMS, and energy management systems — with no cloud dependency.
Common questions about data center environmental monitoring.
Yes. RF Code sensors are completely wire-free — battery powered and self-contained. There is no cabling to run, no conduit to install, and no network port needed. They can be installed on live racks and cabinets in minutes without disrupting operations.
RF Code sensors deliver rack-level granularity — not just room-level averages. Sensors can be placed precisely at intake, exhaust, or any point along a rack. This gives you the visibility to identify hot spots that aggregate sensors completely miss.
Alert response time is under 1 second from threshold breach to notification. Alerts are configurable per sensor, per zone, or globally — and can be sent via email, SNMP trap, SMS, or integrated into your DCIM or BMS alerting framework.
Yes. The PinPoint fluid detection sensor (R136) is specifically designed for liquid cooling deployments. It detects both the presence and exact location of fluid along a cable run — critical for catching leaks before they cause damage in high-density liquid-cooled environments.
RF Code sensors and CenterScape software support ASHRAE A2, A3, and A4 thermal envelope compliance reporting. CenterScape automatically compares live readings against the configured ASHRAE class and flags any out-of-envelope conditions in real time.
Yes. CenterScape supports SNMP, MQTT, Modbus, BACnet, and REST API integrations. It can push sensor data to any DCIM, BMS, or energy management system — keeping all systems synchronized with the same real-time data source.
Go deeper on environmental monitoring.
See your data center environment in real time.
Talk to a data center infrastructure specialist about deploying wire-free environmental monitoring across your facilities.