Proven Real-Time
Fluid Leak Detection.
Prevent a leak from becoming an expensive flood. RF Code's fluid detection sensors identify liquid presence and precise locations immediately.
Proven Fluid Leak Detection Solutions
Know about fluid leaks before damage happens. Prevent expensive equipment damage and service downtime.
Presence and Location Awareness
Presence detection or advanced location detection available. Know not just that fluid is present, but exactly where.
Wipe-Dry Reuse
Unlike traditional absorbic rope cables, this fluid detection solution uses easy to clean non-absorbic detection strips that can be wiped dry and reused immediately.
Propylene Glycol Support
Reliable detection for a wide variety of fluids and coolants, including mixtures of propylene glycol up to PG50.
RF Code Thin-Film vs. Traditional Rope
See why mission-critical facilities, AI compute clusters, and liquid-cooled data centers are choosing wipe-clean, ultra-thin telemetry strips over legacy rope sensors.
| Fluid Detection Spec | Recommended Standard
RF CodeThin-FilmNon-absorbent film strip + less cabling |
Legacy Approach
Traditional Rope StyleAbsorbent sensor rope & heavy cabling |
|---|---|---|
| Form Factor Ultra Thin Sensor Strip | Ultra-Thin Film Profile Just 1mm thick with an industrial adhesive backing make them easy to deploy and unobtrusive. | Bulky & Intrusive Rope Traditional rope cables are thick and bulky and can get in the way. |
| Liquid Cooling Works with Coolants | PG50 & Below Support Support for high PG mixtures. Reliable detection for PG50 and below. | Struggles > PG25 Coolant Most detection rope struggles above PG25 coolant mixtures. |
| Reusability Fluid Detection Reliability | Wipe-Dry Reusable Film-based detection strips can be easily wiped clean and reused immediately. | Degrades / Replace After 1 Leak Traditional rope cables absorb glycol/coolant and require replacement or bake-out cycles after a single minor leak event. |
| Infrastructure Less Cabling | Less Cable Required Provides high fluid sensor density without the cabling nightmare. | Miles of RS-485 Daisy Chains May require miles of RS-485 and controller daisy-chaining. |
| Deployment Convenient Install & Management | Fast On-Demand Install Install on demand without specialist skills. Available in manageable, flexible strip lengths. | Specialist Labor & Long Lead Times Install may require long lead times and specialist skills. Beware of excessively long rope lengths. |
| Protocols Flexible Integration Options | Multi-Protocol Simultaneous Simultaneously integrate with multiple systems using many protocols (SNMP, MQTT, Modbus, BACnet, REST API). | Single Protocol Lock-in May require protocol selection in advance and provide support for a single protocol only |
| Economics Competitively Priced | High Density & Lower TCO Competitive sensor prices and high sensor density options. | High Capex & Replacement Costs Most solutions cannot compete on sensor price and overall sensor density. |
Engineered for AI Density, Liquid Cooling & Immediate Post-Incident Recovery
While traditional rope sensors degrade upon glycol exposure and turn every leak into a costly sensor replacement project, RF Code's thin-film strips wipe clean and resume monitoring in seconds — without physical wiring nightmares.
Proven fluid detection for mission critical facilities
Deploy fluid detection for data centers, manufacturing and more with less physical cabling and higher reliability than traditional rope style detection.
Fluid Detection — Presence (spot)
Detects presence of fluid where the sensor is installed. Ultra thin sensor strip. Fast, convenient installation without the need for specialist tools or copper runs across dense racks.
Data Centers (AI, NeoCloud, High Performance Compute, Enterprise, Colocation, Edge), industrial fluid protection, labs, manufacturing, chip fabs and more. Protect a single asset, a single equipment item or an isolated area.
Fluid Detection — Location
Detects location of fluid along the lenth of the strip. Available in long lengths. Film-based, hassle-free installation. Tells you exactly where the leak is, not just that one exists.
Data Centers (AI, NeoCloud, High Performance Compute, Enterprise, Colocation, Edge), industrial fluid protection, labs, manufacturing, chip fabs and more. Perfect for long runs of racks, or larger areas.
Good reasons to contact RF Code
Why leading organizations deploy RF Code monitoring and tracking solutions in their data centers.
Area & Perimeter Monitoring
Install sensor strips along facility perimeters, under raised floors, or around leak-prone infrastructure to detect leaks before they spread.
Liquid Cooled Racks & Direct-to-Chip
Install at each liquid cooled rack to detect leaks at the source. Critical when deploying high density AI hardware. RF Code has the only solution that will tell where the leak is and exactly what assets are at risk.
Cooling Distribution Units (CDU)
Install around CDUs to provide protection against leaks in coolant distribution.
Coolant Pipes & Plumbing
Install on or under pipes to detect leaks in coolant delivery, return lines and plumbing.
Labs & R&D
Essential for labs where fluid leaks can damage sensitive equipment and interrupt research.
Chip Fabs
Critical for protecting expensive chip processing equipment from fluid leaks.
Protection from fluid risks.
Connect with fluid detection experts to discuss custom sensor placements, liquid cooling telemetry, and fast deployment across your facility.
Instant Contact Alerts
Fast alerting ensures rapid incident response before fluid causes damage.
Wipe-Dry & Reusable
Durable sensor strips wipe dry for long life and reuse.
Coolant & Glycol Ready
Engineered for high-density AI clusters, and works for most fluid detection needs - up to PG50.
Universal Telemetry Integration
Effortless feeds into BMS, DCIM, and ITSM via SNMP, MQTT, Modbus, BACnet, or REST API.